GDS-2000A Programming Manual
146
Parameter/Return
parameter
TRIGger:LOGic:FUNCtion AND
Sets the logic function to AND.
:TRIGger:LOGic:INPut:CLOCK:SOURce
Sets or queries which channel is used as the clock
source.
When “NONe” is selected as the clock source the
trigger will use the Pattern trigger type. (This is the
equivalent of the Data trigger on the scope panel)
:TRIGger:LOGic:INPut:CLOCK:SOURce {NONe | D0 |
D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D 9 | D10 | D11 |
D12 | D13 | D14 | D15 | ? }
:TRIGger:LOGic:INPut:CLOCK:SOURce
:TRIGger:LOGic:INPut:CLOCK:EDGe
Parameter/Return
parameter
No clock source, Set to pattern (data)
trigger.
Digital channels D0 to D15
:TRIGger:LOGic:INPut:CLOCK:SOURce D0
:TRIGger:LOGic:INPut:CLOCK:EDGe FALL
Returns the conditions that are used to generate a
logic pattern trigger with respect to the defined
input pattern and identifies the time at which the
selected pattern may be true and still generate a
trigger.