Examples:
:DCContinue:RTIMe 5.0 set the CDC ramp time to 5 sec.
:DCContinue:RTIMe? return 005.0 if the CDC ramp time setting is 5 sec.
:ACWStanding:VOLTage
Function:
Set or query the ACW test voltage.
Syntax:
:ACWStanding:VOLTage <NR2>
:ACWStanding:VOLTage?
<NR2> Please refer to the specification
Return:
<NR2>
Examples:
: ACWStanding:VOLTage 1.000 set the ACW test voltage to 1.000kV.
: ACWStanding:VOLTage return 1.000 if the CAC test voltage setting is
1.000kV.
:ACWStanding:CMINimum
Function:
Set or query the ACW test minimum current.
Syntax:
:ACWStanding:CMINimum <NR2>
GPI/GPT SERIES PROGRAMMABLE EST
PROGRAMMER MANUAL
40
:ACWStanding:CMINimum?
<NR2> Please refer to the specification
Return:
<NR2>
Examples:
:ACWStanding:CMINimum 1.00 set the ACW test minimum current to 1.00mA.
:ACWStanding:CMINimum? return 01.00 if the ACW test minimum current
setting is 1.00mA.
:ACWstanding:CMAXimum
Function:
Set or query the ACW test maximum current.
Syntax:
:ACWStanding:CMAXimum <NR2>
:ACWStanding:CMAXimum?
<NR2> Please refer to the specification
Return:
<NR2>
Examples:
:ACWStanding:CMAXimum 1.00 set the ACW test maximum current to 1.00mA.
:ACWStanding:CMAXimum? return 01.00 if the ACW test maximum current
setting is 1.00mA.