Gw-instek PSU-Series Programming User Manual Manuale Utente Pagina 78

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 128
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 77
PSU Programming Manual
78
[:SOURce]:CURRent[:LEVel]:TRIGgered
[:AMPLitude]
Set
Query
Description
Syntax
Query Syntax
Parameter
<NR2>
0%~105% of the rated current output in amps.
MIN
Minimum current level.
MAX
Maximum current level.
Return Parameter
<NR2>
Returns the current level.
Example
[:SOURce]:CURRent:LIMit:AUTO
Set
Query
Description
Syntax
Query Syntax
Parameter
OFF | 0
Disable the setting current limit
ON | 1
Enable the setting current limit
Return parameter
<bool>
Returns the setting in <bool> format.
Example
[:SOURce]:CURRent:PROTection:DELay
Set
Query
Description
Syntax
Vedere la pagina 77