Gw-instek GSP-930 Programming Manual Manuale Utente Pagina 150

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 195
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 149
GSP-930 Programming Manual
148
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STARt?
Query
Returns the start frequency (refered to the center)
of the selected offset for the additional
requirements of the selected 3GPP SEM test.
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STARt?
<n>
Offset 1 to 5
<NR3>
Start frequency in Hz
:SEM:OFFS1:ADD:FREQ:STAR?
>2.5e+6
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STOP?
Query
Returns the stop frequency (refered to the center)
of the selected offset for the additional
requirements of the selected 3GPP SEM test.
[:SENSe]:SEMask:OFFSet<n>:ADDition:
FREQuency:STOP?
<n>
Offset 1 to 5
<NR3>
Stop frequency in Hz
:SEM:OFFS1:ADD:FREQ:STOP?
>3.5e+6
Vedere la pagina 149
1 2 ... 145 146 147 148 149 150 151 152 153 154 155 ... 194 195

Commenti su questo manuale

Nessun commento