COMMAND DETAILS
123
:STATus:CHANnel:ENABle
Channel Specific
Command
Description
Sets which events are enabled in the Channel
Status Enable register. The mask values are the bit
weights of the Channel Status Enable Register. See
page 164 for details.
Syntax
:STATus:CHANnel:ENABle <NR1>
Parameter
<NR1>
Event
<NR1>
Event
1
OC
16
OT
2
OV
32
G/N
4
OP
64
UVP
8
RV
128~65535
Not Used
Example
:STAT:CHAN:ENAB 12
Events OP (Bit 3) and RV
(Bit 4) are enabled in the
Channel Status Enable
register.
Query Syntax
:STATus:CHANnel:ENABle? <NR1>
Return Parameter
<NR1>
Event
<NR1>
Event
1
OC
16
OT
2
OV
32
G/N
4
OP
64
UVP
8
RV
128~65535
Not Used
Query Example
:STAT:CHAN:ENAB?
4
The OP event is enabled.
:STATus:CHANnel:EVENt?
Channel Specific
Command
Description
Returns the status of the Channel Status Event
register for the specific channel. The Channel
Status Event register is cleared upon reading.
Query Syntax
:STATus:CHANnel:EVENt? <NR1>
Vedere la pagina 122