:UTILity:AUTO:MODE
System Command
Description
Sets the mainframe auto mode as load or program.
Upon startup the mainframe can automatically
turn on loads or automatically run the last
program.
Syntax
:UTILity:AUTO:MODE {PROGRAM|0|LOAD|1}
Parameter
PROGRAM/0
Sets the auto load mode to
program
LOAD/1
Sets the auto load mode to
load.
Example
:UTIL:AUTO:MODE 1
Auto load mode is set to
load.
Query Syntax
:UTILity:AUTO:MODE?
Return Parameter
<NR1>
Auto load mode
0
Program
1
Load
Query Example
:UTIL:AUTO:MODE?
0
Auto load mode is set to
Program.
:UTILity:SOUNd
System Command
Description
Turns the sound on/off for the mainframe/load
modules.
Syntax
:UTILity:SOUNd {OFF|0|ON|1}
Parameter
OFF/0
Turns sound off
ON/1
Turns sound on
Example
:UTIL:SOUN 1
Turns sound on.
Query Syntax
:UTILity:SOUNd?
Return Parameter
<NR1>
Sound
0
Off