COMMAND DETAILS
139
Query Syntax
:POW:LOW:CURRent? [MAX|MIN]
Return Parameter
<NR2> [MAX|MIN]
Current
1 unit = 1 amp
Returns the current limit.
MAX/MIN
Returns the allowable
maximum and minimum.
Query Example
:POW:LOW:CURR?
7.0
Returns the current limit
for the specific channel.
:POWer:HIGH:AVALue/BVALue
Channel Specific
Command
Description
Sets the high range A/B Value for constant power
mode.
Syntax
:POWer:HIGH:AVALue/BVALue <NRf+>[W]
Parameter
NRf+[W]
AVALue 1
Sets A Value to 1 watt.
BVALue 1W
Sets B Value to 1 watt.
AVALue MIN
Sets A Value to the
minimum level for the
specific channel.
AVALue MAX
Sets A Value to the
maximum Level for the
specific channel.
Example
:POWer:HIGH:AVAL 1
Sets A Value to 1 watt
for the high range.
Query Syntax
:POWer:LOW:AVALue/BVALue? [MAX|MIN]
Return Parameter
<NR2> [MAX|MIN]
Current
1 unit = 1 watt
Returns the power of the A
or B Value.
MAX/MIN
Returns the allowable
maximum and minimum.
Vedere la pagina 138