90
:OCP:CHANnel:LAST
Channel Specific
Command
Description
Queries or sets the current value for after the
DUT OCP protection has been activated.
Syntax
:OCP:CHANnel:LAST {<NRf>[ A ] | MIN | MAX}
Parameter
<NRF>[A]
The current value in Amps.
MAX
The maximum current value.
MIN
The minimum current value.
Example
:OCP:CHAN:LAST MAX
Set the current value to
the maximum value.
Query Syntax
:OCP:CHANnel:LAST?
Return Parameter
<NR2>
Returns the current value in Amps.
Query Example
:OCP:CHAN:LAST?
3.0
Returns the current
value.
:OCP:CHANnel:STEP:TIME
Channel Specific
Command
Description
Queries or sets how long the step time is for the
OCP Test Automation.
Syntax
:OCP:CHANnel:STEP:TIME {<NRf>[ S ] | MIN | MAX}
Parameter
<NRF>[S]
The step time in seconds
(50mS~1600S).
MAX
The maximum step time.
MIN
The minimum step time.
Example
:OCP:CHAN:STEP:TIME
MIN
Set the step time to the
maximum value.
Query Syntax
:OCP:CHANnel:STEP:TIME?
Return Parameter
<NR2>
Returns the step time in seconds.
Query Example
:OCP:CHAN:STEP:TIME?
10.0
Returns the step time.